Demo

Principal Engineer (Fire Protection Design Engineer / Suppression Systems

Pinnacle Specialty Group, Inc.
Aiken, SC Full Time
POSTED ON 3/6/2025
AVAILABLE BEFORE 6/2/2025

Pinnacle Specialty Group is a woman-owned and operated small business specializing in providing project and contract management for Professional, Technical, Engineering, IT and Support Services. We offer full benefits to include : Medical, Dental, Vision, Paid Time Off, 401K - Company Matched.

Duties / Responsibilities :

Provide design engineering staff augmentation support to SRNS. Primary responsibilities include engineering task analysis, walk-downs, design development and generation of design output documents including but not limited to : Plan Drawings, Elevation Drawings, Piping Isometrics, Piping & Instrumentation Diagrams, Riser Details, Hydraulic Calculations (manual and electronically using "HASS" software), and Sway Brace Calculations in accordance with NFPA codes and standards. Provide technical support to site construction forces, start-up & testing, suppliers or subcontract personnel. Prepare Data Sheets, Statements of Work, Procurement Specifications, Design Build Specifications, and Purchase Requisitions.

Engineering services shall be provided using SRNS processes and procedures. Programmatic guidance will be provided by SRNS.

Work Hours : Up to 40-hour work week is scheduled. SRNS utilizes various work schedules

including 5 / 8s (8 hour / day; five days per week), 4 / l0's (10 hours / day; four days per week), and

9 / 80's (9 hours / day, five days on week AA and four days on week BB. Work week excludes SRNS holidays. Each workday has 30-minute lunch. Overtime will be expected at times to meet deliverables

and will be utilized at the discretion of the Manager.

REQUIRED QUALIFICATIONS

Education :

Candidates functioning as Fire Protection Engineers shall be graduates of an ABET accredited Fire Protection Engineering program. If not such a graduate, candidate must be a Registered Professional Engineer in Fire Protection.

Candidates possessing Professional or Fellow membership in the Society of Fire Protection Engineers (SFPE) or a NICET Level III / IV certification in Special Hazard Systems or Water-Based Suppression Systems are deemed to have met the above requirements.

Experience / Skills :

Candidate must demonstrate ten (10) years recent design experience, four (4) of which shall be in the following area of expertise :

Special Hazard Systems / Water-Based Suppression Systems Design

  • General knowledge of mechanical systems, P&ID development, pump calculations, line sizing, and mechanical equipment sizing calculations.
  • Capable of performing hydraulic calculations both manually and electronically using HASS software
  • Capable of becoming Radiological Worker Training Level II qualified.

Additional skills required :

  • Working knowledge of NFPA Codes and Standards, and National Consensus Codes and
  • Standards such as NFPA 13, NFPA 70, NFPA 72, NFPA 90A, NFPA 101, IBC, and various other ISA and IEEE standards

  • Experience with 2D MicroStation Computer Aided Drafting and Design (CADD)
  • Ability to operate Windows Microsoft Office Applications
  • Candidate must be able to perform weekly field walk downs of the job site for the engineering work being performed. These walk downs may involve construction sites with uneven surfaces and work in progress, walking for distances of over half a mile, climbing of ladders to access remote areas, dressing out in protective clothing and environments where a respirator is required.

    OTHER REQUIRED QUALIFICATIONS

    Area Security Access : Candidate must be able to obtain and maintain a DOE "Q" security clearance. An active DOE clearance is not initially required to perform assigned duties. After award, the selected candidate will be notified when to apply for a clearance based on specific work assignments.

    PREFERRED QUALIFICATIONS

    Possession of an active DOE clearance (L or Q) within the past two (2) years is preferred.

    PREFERRED QUALIFICATIONS (SPECIFIC FOR THE POSTING)

  • Previous SRS Design Engineering or DOE facility experience
  • Proficiency in using MicroStation 2D Computer Aided Drafting and Design (CADD) software.
  • Previous SRS design experience and familiarity with the processes and procedures for providing
  • Engineering support to SRS facilities.
  • Work Environment / Physical Demands :

    Work is performed in an office environment and requires the ability to operate standard office equipment and keyboards. Light to moderate lifting may be required for packages and other items, ability to walk short distances, may be regularly required to stand, sit, talk, hear, reach, stoop, kneel, and use hands and fingers to operate a computer, telephone, and keyboard.

    Due to government and / or federal regulations for this position, proof of U.S. citizenship is required.

    We are an Equal Opportunity Employer

    Pinnacle Specialty Group's internal recruiting team requests that staffing / recruiting firms or agencies please not respond to our solicitations.

    If your compensation planning software is too rigid to deploy winning incentive strategies, it’s time to find an adaptable solution. Compensation Planning
    Enhance your organization's compensation strategy with salary data sets that HR and team managers can use to pay your staff right. Surveys & Data Sets

    What is the career path for a Principal Engineer (Fire Protection Design Engineer / Suppression Systems?

    Sign up to receive alerts about other jobs on the Principal Engineer (Fire Protection Design Engineer / Suppression Systems career path by checking the boxes next to the positions that interest you.
    Income Estimation: 
    $162,237 - $199,353
    Income Estimation: 
    $222,110 - $256,974
    Income Estimation: 
    $224,976 - $270,947
    Income Estimation: 
    $205,834 - $254,869
    Income Estimation: 
    $242,530 - $287,120
    Income Estimation: 
    $86,835 - $106,101
    Income Estimation: 
    $110,316 - $137,631
    Income Estimation: 
    $85,996 - $102,718
    Income Estimation: 
    $111,859 - $131,446
    Income Estimation: 
    $110,457 - $133,106
    Income Estimation: 
    $105,809 - $128,724
    Income Estimation: 
    $122,763 - $145,698
    Income Estimation: 
    $105,809 - $128,724
    Income Estimation: 
    $136,611 - $163,397
    Income Estimation: 
    $135,163 - $163,519
    Income Estimation: 
    $131,953 - $159,624
    Income Estimation: 
    $150,859 - $181,127
    Income Estimation: 
    $110,316 - $137,631
    Income Estimation: 
    $137,294 - $170,650
    View Core, Job Family, and Industry Job Skills and Competency Data for more than 15,000 Job Titles Skills Library

    Job openings at Pinnacle Specialty Group, Inc.

    Pinnacle Specialty Group, Inc.
    Hired Organization Address Greenville, SC Full Time
    Pinnacle Specialty Group is a woman-owned and operated small business specializing in providing project and contract man...
    Pinnacle Specialty Group, Inc.
    Hired Organization Address Ridge, TN Full Time
    Pinnacle Specialty Group is a woman-owned and operated small business specializing in providing project and contract man...
    Pinnacle Specialty Group, Inc.
    Hired Organization Address Aiken, SC Full Time
    Pinnacle Specialty Group is a woman-owned and operated small business specializing in providing project and contract man...
    Pinnacle Specialty Group, Inc.
    Hired Organization Address Aiken, SC Full Time
    Pinnacle Specialty Group is a woman-owned and operated small business specializing in providing project and contract man...

    Not the job you're looking for? Here are some other Principal Engineer (Fire Protection Design Engineer / Suppression Systems jobs in the Aiken, SC area that may be a better fit.

    Principal Engineer - Fire Protection Design Engineer

    Longenecker & Associates, Aiken, SC

    AI Assistant is available now!

    Feel free to start your new journey!